Rabu, 27 Agustus 2014

repair MIXER

The working principle of the mixer is similar to the workings of the other electronic devices, such as blenders or fans, which converts electrical energy into mechanical energy / motion, electric current flows from the outlet connecting cable to be routed to the speed selector switch and the motor windings. before we go to the core of the discussion is how to fix the mixer would be much better if we know the first parts of the mixer for easy repair process.

The parts mixer (the outside):

Connecting cable to an electrical outlet
Electric motor speed control buttons
Stirring device, in the form of two pieces of iron rods or spiral-shaped end plate tapered cross each other up.
The parts mixer (inside):
motor drive
capacitor bank
Switch / motor speed regulator swich
The damage that commonly occurs in the mixer
total dead
Motor rotation is slow or
Halting the motor rotation

How to fix:

Mixer total dead,
In a complaint like this, there are several factors that can be the cause, such as: connecting cable broke and the drive motor is broken or burned, to know the damage it must be checked sequentially, namely:
Connecting cable to the electrical outlet, physically see if any of the wires are broke? The connecting cable is usually dropped due to rat bite or pinned object with a heavy load so that the cable is damaged, then when the interest will drop.
If the cable is in good condition, the examination can be followed by looking at the components that exist in the body of the mixer, to be able to view the content that is in the mixer then we have to open all the screws that are outside the body using a screwdriver plus. Then after that check the cable disconnected or not? broke apart there may be less tight cables attached to the terminal
Motor drive, see if the condition of the motor windings to look natural or look like a burnt charred black and smells like burnt already? Such conditions are usually winding on the motor disconnected from the heat that exceeds the strength of the wire windings, but to be sure it is necessary inspection / measurement using AVO meter, remove the cables attached to the drive motor then measure both ends of the motor windings using avometer by moving the position swich at RX 1 kilo ohms, attach the two ends of the probe AVO to both ends of the motor windings, when the AVO meter needle moves to the right and silent on a scale of 0-3, the possibility of the motor is still good, but when the needle on avometer silent / no then most likely move on the motor windings disconnected then so should should re-wrapped or replaced with a new motor.
Motor rotation is slow or halting
For a mixer with round halting or slow rotation, the probable cause is carbon brush is thin (electrical connector component of the cable connecting to the motor), the depletion of the carbon brush is then supplied to the motor windings are connected to the state and not connected, for anticipate this is to replace the carbon brush is already thin with the new
There are different sizes of carbon brush on the market so make sure you bring along examples of carbon brush holder to a store that sells electronic equipment, if it does not find the same size then buy carbon brush is a little bigger than the size of the original , because we are still able to overcome that is by way of filing or mengampelasnya to get a size similar to the size of the original.
If the carbon brush no problem other possibility is that the capacitor bank has been damaged, for that is to replace it with a new one, and thus the motor rotation will be back to normal.